gas furnace wont turn on -this is a photo of the inside of a gas furnce draft inducer. the draft inducer pulls air and burnt gasses through the heat exchanger and out through the vent. this inducer motor was replaced with a new one
We work on all makes and models of free standing gas furnaces and wall furnaces. We carry common repair parts on our vehicles and can fix most furnace repair issues quickly. We can suggest ongoing furnace service a furnace deep cleaning to fix underlying issues that may be causing furnace components to fail.

How Much Does It Cost To Repair a Furnace?

The cost to repair a furnace ranges between $350 to $1100 for complicated repairs. Most furnace repairs are on the low end of that range unless we have to replace an expensive part or parts like a blower motor or control board.

Gas Furnace Startup

Once a year,  annual furnace maintenance is recommended for your gas furnace. When we start your furnace we check all stages of operation, clean the furnace, replace filters, check CO levels in the exhaust vent and inside at the registers. We can tell if your furnace has been derated properly for Albuquerque’s altitude and derate it if needed.

gas furnace repair and service - this is a photograph of a furnace control board. on the control board you can see where a couple of the terminals show signs of an electricl short. this electrical short was caused by a bad furnace draft inducer motor that has seized up. the furnace control board did not have a fuse on it. the new furnace control board is a universal model that fits multiple brands of furnaces. the inducer motor and the control board were repaced.

How Often Should A Gas Furnace Be Serviced?

A gas furnace should be serviced at least once a year. With a service contract we look at the furnace in both the spring and fall. When we service your furnace everything gets a thorough examination and cleaning. If we identify any furnace issues your technician will explain what needs to be done to correct them.

furnace running but no heat
furnace wont start
Gas furnace repair Albuquerque. This is a photo of an old probably over 35 year gravity furnace that is installed in a customers utility closet next to a 50 gallon natural gas water heater. The two share a common vent which exits outside on the roof. An estimate was given to replace this 80,000 btu gas furnace with a newer more efficient model. The venting will be rebuilt as it shares a common vent with a water heater and the vent needs to be upsized to meet current code.
furnace blowing cold air